SUS304/SUS316L ISO Class 5 (Grade A) vertical laminar downflow booths with 10–15% negative-pressure bleed exhaust for OEB 3/4 powder APIs, excipients & cosmetics.
Guangzhou Hengtai (HENGTAI CLEAN) manufactures modular SUS304 and SUS316L Negative-Pressure Downflow Weighing, Sampling & Dispensing Booths (RLAF / Downflow Booths) engineered to protect simultaneously the product (ISO Class 5 / EU GMP Grade A vertical laminar stream), the operator (sweeping airborne API/powder plumes downward away from the breathing zone to < 10–50 µg/m³ TWA), and the adjacent warehouse/cleanroom (-5 to -15 Pa inward air curtain via 10%–15% HEPA-filtered bleed exhaust).

Q_downflow (m³/h) = W_inner × D_inner × 0.45 m/s × 3,600 · Q_bleed_exhaust = 0.10 to 0.15 × Q_downflow. For an HT-WDB-2000 (2.0 × 2.0 m = 4.0 m²) booth, ceiling H14 downflow equals 6,480 m³/h, low-wall G4+F8 return captures 6,480 m³/h at ankle/drum height, and ~750 m³/h bleeds out through a top H13/H14 exhaust damper—creating an inward air barrier across the PVC strip or sliding-door front without ducting externally unless solvent vapors are present.
| Model | Internal Work Zone (W×D×H) | External Footprint (W×D×H) | Filtration Stages & Velocity | Power, Noise & Control | Engineering BOQ Basis |
|---|---|---|---|---|---|
| HT-WDB-1500 | 1500 × 1500 × 2100 mm | 1620 × 1950 × 2450 mm | G4 + F8 Bag + Gel-Seal H14 + PLF Screen · 0.45 m/s ±20% | EC Blower 1.1 kW · ≤ 60 dB(A) · Siemens 7" HMI | Custom BOM Quote (24h Itemized BOQ) |
| HT-WDB-2000 | 2000 × 2000 × 2100 mm | 2120 × 2450 × 2450 mm | G4 + F8 + Gel-Seal H14 (99.995% MPPS) + H13 Bleed | Dual EC Blowers 1.8 kW · ≤ 62 dB(A) · Auto VFD Speed | Custom BOM Quote (24h Itemized BOQ) |
| HT-WDB-2500 | 2500 × 2200 × 2200 mm | 2620 × 2680 × 2550 mm | 3-Stage Pre/Med/H14 + PLF Polymeric Equalizer Membrane | EC Array 2.4 kW · Pallet-Jack Floor Flush · PAO Ports | Custom BOM Quote (24h Itemized BOQ) |
| HT-WDB-3000-EX | 3000 × 2500 × 2200 mm | 3120 × 3000 × 2550 mm | Safe-Change BIBO F8/H14 Option + ATEX Ex d IIB T4 | Explosion-Proof Fans & Intrinsically Safe HMI (Solvents) | Custom BOM Quote (24h Itemized BOQ) |
Instead of perforated metal plates that create micro-eddies over analytical balances, our flush translucent PLF tensioned diffuser cloth delivers true piston-like 0.45 m/s laminar downflow with zero scale drift down to 0.001 g precision.
Pitot/thermal velocity sensors continuously adjust EC blower RPM via Siemens PLC as G4, F8, and H14 filters load over 2–3 years, accompanied by three dedicated Dwyer Magnehelic differential pressure gauges and PAO challenge ports.
All HT-WDB booths ship in pre-wired SUS304 double-skin bolted modules that fit through standard 900 mm doors and assemble flush onto your existing epoxy floor—no floor pit required so drum pallet jacks roll straight inside.
91440101MA59M8NW4E · Building EPC Grade-II D244805460 · Decoration/Steel/Environmental Grade-II D344227631 · Safety License GD-JZ [2022]010947.GR202444009466 · ISO 9001:2015 90924Q00571R0M · CE & EAC · 63 National Patents & 19 Software Copyrights.
For non-volatile dry powders (APIs, excipients, food ingredients, pigments), standard HT-WDB booths discharge their 10%–15% HEPA-filtered bleed air directly back into the warehouse or Grade D room—requiring zero external ductwork. For volatile organic solvents or OEB 4 potent compounds, we provide a top flanged spigot for 100% hard-ducted exhaust.
Yes. Because our PLF polymeric diffuser membrane eliminates turbulent jets and our rear-wall low-level return grilles draw air smoothly past the stainless scale table, 0.1 mg to 1 mg analytical and platform scales stabilize without draft shields.
We manufacture ATEX / IECEx / GB Ex d IIB T4 (or IIC T4 for hydrogen/acetylene zones) weighing booths equipped with explosion-proof blowers, Ex-rated LED luminaires, anti-static conductive PVC curtains, and grounded SUS304/316L frames.
Looking for factory-direct pricing without middleman markups? Send our cleanroom HVAC and stainless equipment engineers your layout, target ISO 14644-1 class, or equipment list.
Protect operators and adjacent corridors during raw-material powder drum sampling and API weighing with vertical ISO 5 unidirectional downflow (0.45 m/s) and 10-15% bleed exhaust.
| Cleanroom Class / Subsystem | Target Standard / Capacity | HENGTAI Factory Specification | Primary Application |
|---|---|---|---|
| HT-WDB-2000 Dispensing Booth | 2000x1800x2200 mm SUS304 | G4 + F8 + Gel-Seal H14 + Bleed Exhaust | <50 ug/m3 Operator Breathing Zone |
| Explosion-Proof Weighing Booth | ATEX Ex d IIB T4 Fan & Lighting | Anti-Static Grounded SUS304/316L Workzone | Solvent & Flammable Excipients |
A (HENGTAI Chief Engineer): 90% of air recirculates internally through G4/F8/H14 stages while a 10% top bleed exhaust maintains slight negative pressure inside the booth.