Pre-engineered ISO Class 5 (Class I) surgical laminar ceiling suites, lead-lined hybrid OR walls, automatic hermetic sliding doors and -15 Pa negative-pressure wards shipped in 1×40'HQ kits.
Guangzhou Hengtai (HENGTAI CLEAN · EPC License D244805460) designs and manufactures pre-engineered modular hospital operating theatres (Class I / ISO 5, Class II / ISO 6, Class III / ISO 7), ICUs, CSSD sterile supply centers, and -15 Pa AIIR infectious isolation wards. Every suite integrates an HT-OR SUS304 H14 gel-seal laminar flow ceiling plenum (0.25–0.30 m/s unidirectional downflow over the surgical table), 1.2–1.5 mm antibacterial electrolytic steel or SUS304 wall panels with 45° octagonal utility corners, automatic hermetic sliding doors, medical gas & surgical pendant structural frames, and dedicated hygienic AHUs—proven in overseas hospital turnkeys including our Angola Surgical Center Project (#1152).

Q_supply (m³/h) = A_plenum (m²) × v_face (0.25–0.30 m/s) × 3,600 · For a Class I orthopedic/cardiac/neurosurgical OR using an HT-OR-3026 (3.0 × 2.6 m = 7.8 m²) ceiling canopy at 0.28 m/s, primary laminar supply equals 7,862 m³/h (≥ 20% outdoor fresh air), maintaining +15 to +20 Pa positive pressure relative to the scrub/sub-sterile corridor, ≤ 0.5 CFU/plate (30 min) settle plates, and ≤ 48 dB(A) acoustic comfort.
| Model / Suite Class | Target Standard & ISO Class | Laminar Ceiling Canopy | Airflow / ACH & Pressure | Wall Envelope & Radiation Shield | Engineering BOQ Basis |
|---|---|---|---|---|---|
| HT-OR-I (Class I Ultra-Clean OR) | ISO Class 5 Surgical Zone / ISO 6 Periphery (HTM 03-01 / GB 50333) | 3000 × 2600 mm SUS304 + H14 Gel-Seal + Diffuser Screen | 7,800–9,200 m³/h · 0.25–0.30 m/s · +15 to +20 Pa | 1.2mm Antibacterial Electrolytic Steel + Gypsum/MgO Backing | Custom BOM Quote (24h Itemized BOQ) |
| HT-OR-HB (Hybrid C-Arm / Cath Lab OR) | ISO Class 5/6 + Radiation Protection | 3200 × 2800 mm Split Ring-Track Compatible H14 Canopy | 8,500–10,000 m³/h · +15 Pa · 19–24°C / 40–60% RH | Electrolytic Steel / SUS304 + 2.0–3.0 mm Pb Lead Lining | Custom BOM Quote (24h Itemized BOQ) |
| HT-OR-II (General & OB-GYN OR) | ISO Class 6 Surgical Zone / ISO 7 Periphery | 2400 × 1800 mm SUS304 H14 Laminar Ceiling | 4,200–5,200 m³/h · 30–35 ACH · +10 to +15 Pa | 50mm Class A1 MgO / Electrolytic Steel Flush Modular Wall | Custom BOM Quote (24h Itemized BOQ) |
| HT-OR-III (Day Surgery / Endoscopy) | ISO Class 7 / Class 10,000 | 1800 × 1400 mm Terminal H14 Ceiling Plenum | 2,800–3,500 m³/h · 20–25 ACH · +8 to +12 Pa | 50mm Antibacterial HPL / PPGI Rockwool-MgO Panel | Custom BOM Quote (24h Itemized BOQ) |
| HT-AIIR-N15 (Infectious Isolation Ward) | ASHRAE 170 AIIR · Negative Pressure | 100% Once-Through Supply + Bedhead Low-Level Return | ≥ 12 ACH · -15 Pa Room / -8 Pa Anteroom · BIBO H14 Exhaust | VHP-Resistant PVDF Steel + Hermetic Sliding Door | Custom BOM Quote (24h Itemized BOQ) |
Pre-fabricated corner cavities house recessed medical gas outlets (O2, N2O, Vacuum, MA4, AGSS), 24-inch PACS touch control screens, X-ray LED viewers, and stainless instrument cabinets flush with the wall plane.
Brushless microprocessor hermetic doors compress 4-sided EPDM gaskets down onto the conductive PVC floor and inward against the frame upon closing, paired with 1/2/3-bay SUS304 knee/infrared thermostatic surgical scrub sinks.
Proven in our Angola Hospital Cleanroom Project (#1152): pre-numbered panels, ceiling plenums, shadowless lamp structural flanges, isolated power (IT) transformer cabinets, and hygienic DX/chilled-water AHUs ship ready for 18-day assembly.
91440101MA59M8NW4E · Building EPC Grade-II D244805460 · Decoration/Steel/Environmental Grade-II D344227631 · Safety License GD-JZ [2022]010947.GR202444009466 · ISO 9001:2015 90924Q00571R0M · CE & EAC · 63 National Patents & 19 Software Copyrights.
Every HT-OR modular operating room includes a pre-welded Q235B galvanized structural steel load-bearing bridge rated ≥ 800 kg centralized load above the laminar ceiling center flange, matching Maquet, Mindray, Dräger, or Trumpf mounting bolt patterns.
No. Under DIN 1946-4, HTM 03-01, and GB 50333, each Class I (ISO 5) and septic/negative-pressure operating room is engineered with its own independent hygienic AHU and VFD fresh-air/exhaust dampers to eliminate cross-infection and allow individual standby turndown.
Yes. We factory-laminate 2.0 mm to 3.0 mm Pb (lead equivalent) sheets onto electrolytic steel wall panels, hermetic sliding door cores, and Pb barium-lead vision windows with overlapping lead joint strips for zero radiation leakage.
We supply 2.0 mm homogeneous conductive ESD PVC roll flooring (10^4–10^6 Ω) with copper grounding grids, hot-welded seams, and R50 coved wall skirtings capable of heavy surgical table rolling loads and daily sporicide mopping.
Looking for factory-direct pricing without middleman markups? Send our cleanroom HVAC and stainless equipment engineers your layout, target ISO 14644-1 class, or equipment list.
Prefabricated electrolytic-steel/antibacterial HPL surgical suites, ISO 5 orthopedic laminar ceiling plenums, -15 Pa airborne infection isolation rooms (AIIR), and VOC-free IVF embryology laboratories.
| Cleanroom Class / Subsystem | Target Standard / Capacity | HENGTAI Factory Specification | Primary Application |
|---|---|---|---|
| Class I Orthopedic OT | ISO Class 5 (2600x2400 Laminar Plenum) | 0.25-0.30 m/s Downflow + <=48 dB(A) | Joint Replacement / Cardiac / Neuro |
| Negative-Pressure ICU Ward | -10 to -15 Pa vs Buffer Anteroom | 12 ACH 100% Exhaust via BIBO H14 | Infectious Isolation Compliance |
| IVF Embryology Clean Lab | ISO 6 Particle + Activated Carbon VOC | <0.1 ppm TVOC + Vibration-Isolated Bench | Blastocyst Culture Protection |
A (HENGTAI Chief Engineer): Yes. Flush stainless touchscreen nurse stations (time, anesthesia gas alarms, temperature, RH, HEPA ΔP, X-ray viewer) ship factory-recessed inside wall panels.