Modular Hospital Laminar Operating Theatres, ICU & Isolation Wards

Pre-engineered ISO Class 5 (Class I) surgical laminar ceiling suites, lead-lined hybrid OR walls, automatic hermetic sliding doors and -15 Pa negative-pressure wards shipped in 1×40'HQ kits.

HTM 03-01 / DIN 1946-4ASHRAE 170ISO Class 5 Laminar CeilingGrade-II EPC D244805460
Direct Answer & Engineering Scope · 26,000 m² Guangzhou Base · RMB 38,000,000 Capital

Guangzhou Hengtai (HENGTAI CLEAN · EPC License D244805460) designs and manufactures pre-engineered modular hospital operating theatres (Class I / ISO 5, Class II / ISO 6, Class III / ISO 7), ICUs, CSSD sterile supply centers, and -15 Pa AIIR infectious isolation wards. Every suite integrates an HT-OR SUS304 H14 gel-seal laminar flow ceiling plenum (0.25–0.30 m/s unidirectional downflow over the surgical table), 1.2–1.5 mm antibacterial electrolytic steel or SUS304 wall panels with 45° octagonal utility corners, automatic hermetic sliding doors, medical gas & surgical pendant structural frames, and dedicated hygienic AHUs—proven in overseas hospital turnkeys including our Angola Surgical Center Project (#1152).

HENGTAI CLEAN SUS304 hospital surgical scrub sink and modular operating theatre corridor
Chief Engineer Sizing Criterion (Mr. Tan Shuping · 30+ Yrs)

Surgical Laminar Plenum Sizing & Operating Theatre Pressure Cascade Formula

Q_supply (m³/h) = A_plenum (m²) × v_face (0.25–0.30 m/s) × 3,600 · For a Class I orthopedic/cardiac/neurosurgical OR using an HT-OR-3026 (3.0 × 2.6 m = 7.8 m²) ceiling canopy at 0.28 m/s, primary laminar supply equals 7,862 m³/h (≥ 20% outdoor fresh air), maintaining +15 to +20 Pa positive pressure relative to the scrub/sub-sterile corridor, ≤ 0.5 CFU/plate (30 min) settle plates, and ≤ 48 dB(A) acoustic comfort.

Request 24h Itemized BOQ → Download Spec PDFs

2026 Models, Technical Parameters & Engineering Matrix

Model / Suite ClassTarget Standard & ISO ClassLaminar Ceiling CanopyAirflow / ACH & PressureWall Envelope & Radiation ShieldEngineering BOQ Basis
HT-OR-I (Class I Ultra-Clean OR)ISO Class 5 Surgical Zone / ISO 6 Periphery (HTM 03-01 / GB 50333)3000 × 2600 mm SUS304 + H14 Gel-Seal + Diffuser Screen7,800–9,200 m³/h · 0.25–0.30 m/s · +15 to +20 Pa1.2mm Antibacterial Electrolytic Steel + Gypsum/MgO BackingCustom BOM Quote (24h Itemized BOQ)
HT-OR-HB (Hybrid C-Arm / Cath Lab OR)ISO Class 5/6 + Radiation Protection3200 × 2800 mm Split Ring-Track Compatible H14 Canopy8,500–10,000 m³/h · +15 Pa · 19–24°C / 40–60% RHElectrolytic Steel / SUS304 + 2.0–3.0 mm Pb Lead LiningCustom BOM Quote (24h Itemized BOQ)
HT-OR-II (General & OB-GYN OR)ISO Class 6 Surgical Zone / ISO 7 Periphery2400 × 1800 mm SUS304 H14 Laminar Ceiling4,200–5,200 m³/h · 30–35 ACH · +10 to +15 Pa50mm Class A1 MgO / Electrolytic Steel Flush Modular WallCustom BOM Quote (24h Itemized BOQ)
HT-OR-III (Day Surgery / Endoscopy)ISO Class 7 / Class 10,0001800 × 1400 mm Terminal H14 Ceiling Plenum2,800–3,500 m³/h · 20–25 ACH · +8 to +12 Pa50mm Antibacterial HPL / PPGI Rockwool-MgO PanelCustom BOM Quote (24h Itemized BOQ)
HT-AIIR-N15 (Infectious Isolation Ward)ASHRAE 170 AIIR · Negative Pressure100% Once-Through Supply + Bedhead Low-Level Return≥ 12 ACH · -15 Pa Room / -8 Pa Anteroom · BIBO H14 ExhaustVHP-Resistant PVDF Steel + Hermetic Sliding DoorCustom BOM Quote (24h Itemized BOQ)

Core Manufacturing & Turnkey EPC Advantages

Octagonal 45° Corner Integrated Wall System

Pre-fabricated corner cavities house recessed medical gas outlets (O2, N2O, Vacuum, MA4, AGSS), 24-inch PACS touch control screens, X-ray LED viewers, and stainless instrument cabinets flush with the wall plane.

Hermetic Sliding Doors & Scrub Stations

Brushless microprocessor hermetic doors compress 4-sided EPDM gaskets down onto the conductive PVC floor and inward against the frame upon closing, paired with 1/2/3-bay SUS304 knee/infrared thermostatic surgical scrub sinks.

1×40'HQ Overseas Hospital Fast-Track Kit

Proven in our Angola Hospital Cleanroom Project (#1152): pre-numbered panels, ceiling plenums, shadowless lamp structural flanges, isolated power (IT) transformer cabinets, and hygienic DX/chilled-water AHUs ship ready for 18-day assembly.

Verified Credentials & Factory Acceptance Testing (FAT)

  • Licensed EPC Entity: Unified Social Credit Code 91440101MA59M8NW4E · Building EPC Grade-II D244805460 · Decoration/Steel/Environmental Grade-II D344227631 · Safety License GD-JZ [2022]010947.
  • Patented Manufacturing: National High-Tech Enterprise GR202444009466 · ISO 9001:2015 90924Q00571R0M · CE & EAC · 63 National Patents & 19 Software Copyrights.
  • Pre-Shipment Inspection: Full EN 1822 MPPS HEPA scan logs, airflow velocity uniformity mapping, PLC interlock test video, and third-party SGS / BV / TÜV witness welcome.
Hermetic cleanroom window and electrolytic steel hospital operating room wall system

Frequently Asked Engineering & Procurement Questions

How do you coordinate the ceiling structural frame for shadowless surgical lights and anesthesia pendants?

Every HT-OR modular operating room includes a pre-welded Q235B galvanized structural steel load-bearing bridge rated ≥ 800 kg centralized load above the laminar ceiling center flange, matching Maquet, Mindray, Dräger, or Trumpf mounting bolt patterns.

Can one AHU serve multiple Class I operating theatres?

No. Under DIN 1946-4, HTM 03-01, and GB 50333, each Class I (ISO 5) and septic/negative-pressure operating room is engineered with its own independent hygienic AHU and VFD fresh-air/exhaust dampers to eliminate cross-infection and allow individual standby turndown.

Do you supply lead-lined walls and doors for Hybrid ORs and Cath Labs?

Yes. We factory-laminate 2.0 mm to 3.0 mm Pb (lead equivalent) sheets onto electrolytic steel wall panels, hermetic sliding door cores, and Pb barium-lead vision windows with overlapping lead joint strips for zero radiation leakage.

What floor system is included in an overseas hospital operating theatre kit?

We supply 2.0 mm homogeneous conductive ESD PVC roll flooring (10^4–10^6 Ω) with copper grounding grids, hot-welded seams, and R50 coved wall skirtings capable of heavy surgical table rolling loads and daily sporicide mopping.

Explore Related Cleanroom Systems & Specialized Hardware

Cytotoxic Safety Cabinets & USP 800 Isolators →GLP SPF Animal Vivarium & BSL-2/3 Lab EPC →Lithium & Solid-State Battery Dry Cleanroom (-65°C DP) →GMP Negative-Pressure Weighing & Sampling Booth →ISO 5 Laminar Flow Clean Bench & LAF Canopy →GMP R&D, Microbiology Lab EPC & VAV Fume Hoods →ASME BPE SUS316L Sanitary Process Piping & PW/WFI Loops →
Direct China Manufacturer · Grade-II EPC License D244805460 · ISO 9001 & CE

Request a 24-Hour Turnkey Cleanroom & Equipment BOQ

Looking for factory-direct pricing without middleman markups? Send our cleanroom HVAC and stainless equipment engineers your layout, target ISO 14644-1 class, or equipment list.

  • Stage-1 Budgetary Quote in 4–24 Hours: Itemized EXW / FOB Guangzhou / CIF / DDP unit pricing & container load plan.
  • Free Engineering Value-Add: AutoCAD room pressure cascade review, CFM/ACH air-change calculation & utility matrix.
  • Download Technical Dossiers: 6 A4 Engineering Spec Sheets (PDF) →
Direct Engineering Desk (Alex Gao):
Email: · WhatsApp:

Get Factory-Direct Pricing & CAD Support

No obligation · Direct response from senior cleanroom project engineer Alex Gao

By submitting you agree to our privacy policy; we use your details only to reply to this inquiry.

ISO Class 5 Modular Laminar Operating Theater & Negative-Pressure ICU Matrix

Prefabricated electrolytic-steel/antibacterial HPL surgical suites, ISO 5 orthopedic laminar ceiling plenums, -15 Pa airborne infection isolation rooms (AIIR), and VOC-free IVF embryology laboratories.

Cleanroom Class / SubsystemTarget Standard / CapacityHENGTAI Factory SpecificationPrimary Application
Class I Orthopedic OTISO Class 5 (2600x2400 Laminar Plenum)0.25-0.30 m/s Downflow + <=48 dB(A)Joint Replacement / Cardiac / Neuro
Negative-Pressure ICU Ward-10 to -15 Pa vs Buffer Anteroom12 ACH 100% Exhaust via BIBO H14Infectious Isolation Compliance
IVF Embryology Clean LabISO 6 Particle + Activated Carbon VOC<0.1 ppm TVOC + Vibration-Isolated BenchBlastocyst Culture Protection

Q: Do modular hospital operating theaters integrate medical gas pendants and surgeon control panels?

A (HENGTAI Chief Engineer): Yes. Flush stainless touchscreen nurse stations (time, anesthesia gas alarms, temperature, RH, HEPA ΔP, X-ray viewer) ship factory-recessed inside wall panels.