AAALAC / GLP SPF Animal Vivarium & BSL-2 / BSL-3 Biosafety Cleanrooms

Airtight VHP-ready barrier envelopes, 100% once-through fresh-air heat-recovery AHUs, IVC rack exhaust integration, pneumatic seal doors and BIBO H14 containment.

AAALAC / OECD GLPCDC BMBL BSL-2 / BSL-3Ammonia < 14 mg/m³VHP & BIBO Containment
Direct Answer & Engineering Scope · 26,000 m² Guangzhou Base · RMB 38,000,000 Capital

Guangzhou Hengtai (HENGTAI CLEAN · Grade-II EPC D244805460) engineers and fabricates turnkey AAALAC / OECD GLP Specific-Pathogen-Free (SPF) rodent & large-animal barrier vivariums as well as BSL-2, ABSL-2, and BSL-3 biological safety containment laboratories. Our systems solve the three hardest vivarium & biosafety challenges: 100% non-recirculating fresh-air conditioning with glycol run-around / plate sensible heat recovery, ultra-tight ammonia & odor control (≤ 14 mg/m³), and gas-tight PVDF/SUS304 rooms with pneumatic inflatable-seal doors, double-door pass-through autoclaves, dunk tanks, and SUS316L Bag-In/Bag-Out (BIBO) H14 exhaust filtration.

1:1 CAD to 3D BIM to actual GLP clean laboratory built by Guangzhou Hengtai
Chief Engineer Sizing Criterion (Mr. Tan Shuping · 30+ Yrs)

Vivarium 100% Once-Through Fresh Air & BSL-3 Directional Negative Cascade

SPF Positive Barrier Cascade: Clean Corridor (+25 Pa) → Animal Holding Room (+15 Pa, 15–20 ACH, 20–26°C ±1°C, 40–70% RH, ≤ 50 dB(A)) → Dirty Return Corridor (+5 Pa). BSL-3 / ABSL-3 Negative Containment Cascade: Clean Change (0 Pa) → Shower Airlock (-15 Pa) → Inner Corridor (-30 Pa) → Core BSL-3 Lab (-45 to -60 Pa, redundant N+1 VFD exhaust blowers interlocked with supply fan).

Request 24h Itemized BOQ → Download Spec PDFs

2026 Models, Technical Parameters & Engineering Matrix

Facility ConfigurationCompliance StandardPressure Regime & Air ChangesEnvelope & Door SystemExhaust & Sterilization HardwareEngineering BOQ Basis
HT-VIV-SPF (SPF Rodent IVC Barrier)AAALAC / OECD GLP / GB 14925 · ISO 7+25 / +15 / +5 Pa Positive · 15–20 ACH (100% Fresh Air)50mm PVDF Antibacterial MgO Panel + Vision GlassThimble Exhaust to IVC Racks + Activated Carbon + VHP Pass BoxCustom BOM Quote (24h Itemized BOQ)
HT-VIV-LA (Large Animal GLP Suite)OECD GLP Preclinical (NHP / Canine / Porcine)+15 Pa Barrier or -15 Pa Quarantine · 18–25 ACHSUS304 Brushed 1.0mm Impact-Resistant Wall + Epoxy CoveHose-Washdown Drains + Ozone/Glycol Heat-Recovery AHUCustom BOM Quote (24h Itemized BOQ)
HT-BSL-2P (Enhanced BSL-2 / PCR / Viral)WHO LBM4 / CDC BMBL BSL-2+ · ISO 7/8-10 Pa Buffer / -25 Pa Core Lab · 12–18 ACH50mm Class A1 Rockwool-MgO Flush Wall + Interlocked DoorsClass II A2/B2 BSC + Dynamic Pass Box + HEPA ExhaustCustom BOM Quote (24h Itemized BOQ)
HT-BSL-3M (Modular Containerized / Fixed BSL-3)CDC BMBL 6th Ed. BSL-3 / GB 50346-15 / -30 / -45 Pa Directional · N+1 Redundant ExhaustWelded SUS304 / PVDF Airtight Envelope + Pneumatic Seal DoorSUS316L Dual BIBO H14 Housing + Double-Door Autoclave + Dunk TankCustom BOM Quote (24h Itemized BOQ)

Core Manufacturing & Turnkey EPC Advantages

IVC Thimble Exhaust & Circadian Welfare Control

Direct HVAC balancing with Tecniplast, Allentown, or Shinva Individually Ventilated Cage (IVC) blowers ensures room pressure stability even when cages are docked/undocked, paired with 12h/12h dawn-dusk programmable dual-level LED lighting (15–25 Lux holding / 350 Lux procedure) and ≤ 50 dB(A) silencers.

Zero-Failure N+1 Exhaust Interlock for BSL-3

Siemens S7-1500 redundant PLC controls ensure that if the primary exhaust fan falters, the standby VFD blower ramps to 100% within 2 seconds while simultaneously throttling supply airflow so the core containment room can NEVER flip to positive pressure.

Glycol Run-Around Coil Energy Recovery (Zero Cross-Leakage)

Because 100% once-through fresh air consumes massive cooling/heating energy in tropical ASEAN, 50°C GCC, or -40°C CIS winters, we use closed-loop glycol run-around coils (0% air crossover between exhaust and intake) recovering 52%–60% thermal energy.

Verified Credentials & Factory Acceptance Testing (FAT)

  • Licensed EPC Entity: Unified Social Credit Code 91440101MA59M8NW4E · Building EPC Grade-II D244805460 · Decoration/Steel/Environmental Grade-II D344227631 · Safety License GD-JZ [2022]010947.
  • Patented Manufacturing: National High-Tech Enterprise GR202444009466 · ISO 9001:2015 90924Q00571R0M · CE & EAC · 63 National Patents & 19 Software Copyrights.
  • Pre-Shipment Inspection: Full EN 1822 MPPS HEPA scan logs, airflow velocity uniformity mapping, PLC interlock test video, and third-party SGS / BV / TÜV witness welcome.
VHP bio-decontamination pass box and biosafety transfer airlock

Frequently Asked Engineering & Procurement Questions

Why use glycol run-around heat recovery instead of enthalpy wheels in SPF vivariums and BSL labs?

Rotary enthalpy wheels carry 1%–3% purge/seal carryover between exhaust and fresh supply air—unacceptable for ammonia, allergens, or BSL pathogens. Closed-loop water-glycol coils physically separate supply and exhaust airstreams while recovering over 52% sensible load.

How do you seal penetrations in VHP-fumigated BSL-3 and GLP rooms?

All cable conduits, sensor ports, sprinkler heads, and gas pipes pass through welded SUS316L collar plates sealed with medical-grade RTV neutral silicone and EPDM compression glands, verified via smoke and room pressure-decay testing.

Can a BSL-2 or SPF vivarium be delivered as a pre-fabricated modular kit overseas?

Yes. Our pre-numbered PVDF sandwich panels, pneumatic/gasketed doors, VHP pass boxes, dunk tanks, BIBO filter housings, and 100% fresh-air hygienic AHUs pack into standard 40'HQ containers with 3D BIM assembly drawings.

Explore Related Cleanroom Systems & Specialized Hardware

Modular Hospital Laminar Operating Room EPC →Cytotoxic Safety Cabinets & USP 800 Isolators →Lithium & Solid-State Battery Dry Cleanroom (-65°C DP) →GMP Negative-Pressure Weighing & Sampling Booth →ISO 5 Laminar Flow Clean Bench & LAF Canopy →GMP R&D, Microbiology Lab EPC & VAV Fume Hoods →ASME BPE SUS316L Sanitary Process Piping & PW/WFI Loops →
Direct China Manufacturer · Grade-II EPC License D244805460 · ISO 9001 & CE

Request a 24-Hour Turnkey Cleanroom & Equipment BOQ

Looking for factory-direct pricing without middleman markups? Send our cleanroom HVAC and stainless equipment engineers your layout, target ISO 14644-1 class, or equipment list.

  • Stage-1 Budgetary Quote in 4–24 Hours: Itemized EXW / FOB Guangzhou / CIF / DDP unit pricing & container load plan.
  • Free Engineering Value-Add: AutoCAD room pressure cascade review, CFM/ACH air-change calculation & utility matrix.
  • Download Technical Dossiers: 6 A4 Engineering Spec Sheets (PDF) →
Direct Engineering Desk (Alex Gao):
Email: · WhatsApp:

Get Factory-Direct Pricing & CAD Support

No obligation · Direct response from senior cleanroom project engineer Alex Gao

By submitting you agree to our privacy policy; we use your details only to reply to this inquiry.

BSL-2 / BSL-3 Biosafety, PCR Molecular & GLP Vivarium Cleanroom EPC Matrix

Directional negative-pressure cascade HVAC, pneumatic/inflatable-seal biosafety doors, Bag-In-Bag-Out (BIBO) H14 exhaust housings, and ammonia-scrubbed SPF animal facility air handling.

Cleanroom Class / SubsystemTarget Standard / CapacityHENGTAI Factory SpecificationPrimary Application
PCR 4-Zone Molecular Suite+10 / +5 / -5 / -15 Pa UnidirectionalReagent -> Extraction -> AmplificationZero Amplicon Carryover
BSL-2 / Enhanced BSL-3 Suite-30 to -50 Pa Core ContainmentDual Redundant Exhaust Fans + BIBO H14Pathogen Containment Safety
SPF / GLP Rodent Vivarium15-20 ACH 100% Fresh Air + IVC DockNH3 < 14 ppm + 12h/12h PhotoperiodAAALAC / GLP Compliant

Q: What happens if the primary exhaust fan trips in a negative-pressure BSL laboratory?

A (HENGTAI Chief Engineer): Automatic VFD lead-lag PLC transfer starts the standby exhaust fan within 2 seconds while modulating supply dampers to prevent positive-pressure reversal.