Turnkey GMP R&D, QC Microbiology Laboratories, VAV Fume Hoods & Lab Furniture

1:1 CAD-to-BIM-to-reality laboratory engineering: ISO 7/ISO 5 sterility & microbial limit suites, 0.50 m/s VAV fume hoods, Trespa island benches & exhaust scrubbers.

ISO/IEC 17025 & GMP QCASHRAE 110 VAV Fume HoodsSterility & PCR ZoningPROYA / Listed Client Proven
Direct Answer & Engineering Scope · 26,000 m² Guangzhou Base · RMB 38,000,000 Capital

Guangzhou Hengtai (HENGTAI CLEAN · Grade-II EPC D244805460 & Decoration/Environmental Grade-II D344227631) delivers complete R&D formulation, QC physicochemical, HPLC/GC-MS analytical, and GMP microbiology clean laboratories—combining cleanroom zoning, 0.50 m/s Constant-Face-Velocity VAV Fume Hoods, 1.2 mm pickled-phosphated steel & PP polypropylene lab benches, high-purity specialty gas manifolds (N2, He, Ar, H2, Air), and roof wet-scrubber / activated-carbon exhaust treatment under one contract.

PROYA and Befe R&D clean laboratory designed and built by Guangzhou Hengtai
Chief Engineer Sizing Criterion (Mr. Tan Shuping · 30+ Yrs)

GMP Microbiology 3-Suite Separation & VAV Fume Hood Makeup Air Balance

Pharmacopoeial Microbiology Zoning: Sterility Test Suite (ISO 7 / Grade B background + ISO 5 Laminar/Isolator, +15 Pa), Microbial Limit Suite (ISO 7, +10 Pa), and Positive Control / Pathogen Suite (Independent AHU, -10 Pa negative buffer—zero shared return air!). VAV Fume Hood Flow: Q_hood (m³/h) = W_sash × H_open × 0.50 m/s × 3,600 (ranging from 320 m³/h closed standby to 1,450 m³/h at 500 mm sash height with < 1.0 s Venturi/VAV damper tracking to hold room -5 Pa).

Request 24h Itemized BOQ → Download Spec PDFs

2026 Models, Technical Parameters & Engineering Matrix

Subsystem / ModelApplicable StandardDimensions & Core MaterialAirflow / Containment SpecKey FeaturesEngineering BOQ Basis
HT-LAB-MICRO (3-Suite Micro Lab Kit)USP <1117> / ChP / EU GMP QC45–120 m² Modular ISO 7 + ISO 5 SuitesIndependent AHUs for Sterility (+) vs Positive Control (-)Flush Antibacterial Panels + Pass Boxes + InterlocksCustom BOM Quote (24h Itemized BOQ)
HT-LAB-PCR (4-Room Molecular PCR Lab)WHO Molecular DiagnosticsReagent (+10 Pa) → Specimen (-5 Pa) → Amp (-15 Pa) → Product (-25 Pa)100% Unidirectional Workflow + Pass-Box UV InterlocksZero Amplicon Back-Diffusion Pressure CascadeCustom BOM Quote (24h Itemized BOQ)
HT-FH-1500-VAV (Steel VAV Fume Hood)ASHRAE 110 / EN 141751500 × 850 × 2350 mm (1200 / 1800 opt.)0.50 m/s ±10% Constant Face Velocity · Sash Displacement SensorEpoxy Steel + Ceramic Worktop + Phenolic LinerCustom BOM Quote (24h Itemized BOQ)
HT-FH-1500-PP (Acid-Proof PP Fume Hood)Trace Metal / HF / Perchloric1500 × 850 × 2350 mm · 8–12 mm Virgin PP0% Metal Interior · Optional Built-in Mist WashdownSeamless Welded Polypropylene for Strong AcidsCustom BOM Quote (24h Itemized BOQ)
HT-BENCH-C (Island & Wall Lab Benches)SEFA 8M Load Rated (≥ 300 kg/m²)W 750/1500 × H 850 mm Modular Lengths12.7 mm Solid Phenolic (Trespa) / 20 mm Epoxy Resin Top60×40×1.5mm C-Frame Steel + Reagent Rack + PP SinksCustom BOM Quote (24h Itemized BOQ)

Core Manufacturing & Turnkey EPC Advantages

1:1 Fidelity From Chief Designer Liu Wei's 3D BIM to Handover

Delivered for listed cosmetics & biopharma leaders including PROYA and Befe.: curved floor-to-ceiling tempered vision walls, concealed GC/ICP-MS stainless atomic absorption exhaust canopies, and ergonomic island benches.

80% HVAC Energy Reduction With Sash-Linked VAV Fume Hoods

Traditional CAV fume hoods exhaust 1,500 m³/h of conditioned 22°C lab air 24/7 even when nobody stands in front. Our ultrasonic sash-height VAV controllers + room differential pressure makeup tracking cut conditioned makeup air energy by up to 68%.

Roof PP Acid Mist Scrubber + Activated Carbon Exhaust Towers

Complete environmental compliance (License D344227631): NaOH alkaline spray packed-bed towers neutralize HCl/HNO3/H2SO4 inorganic acid fumes while multi-bed honeycomb activated carbon adsorbs VOC solvent vapors.

Verified Credentials & Factory Acceptance Testing (FAT)

  • Licensed EPC Entity: Unified Social Credit Code 91440101MA59M8NW4E · Building EPC Grade-II D244805460 · Decoration/Steel/Environmental Grade-II D344227631 · Safety License GD-JZ [2022]010947.
  • Patented Manufacturing: National High-Tech Enterprise GR202444009466 · ISO 9001:2015 90924Q00571R0M · CE & EAC · 63 National Patents & 19 Software Copyrights.
  • Pre-Shipment Inspection: Full EN 1822 MPPS HEPA scan logs, airflow velocity uniformity mapping, PLC interlock test video, and third-party SGS / BV / TÜV witness welcome.
CAD layout to 3D BIM to actual 1:1 R&D clean laboratory handover by HENGTAI CLEAN

Frequently Asked Engineering & Procurement Questions

Can Sterility Testing and Positive Control rooms share the same AHU in a GMP microbiology lab?

Never. Sharing return ductwork between the Positive Control room (where live Staphylococcus aureus, Pseudomonas aeruginosa, and Candida albicans reference strains are inoculated) and the Sterility Test suite creates false-positive batch failures and immediate GMP critical observations. We supply dedicated compact hygienic AHUs for each zone.

When should I choose a Polypropylene (PP) fume hood over an Epoxy-Coated Steel fume hood?

Choose epoxy-coated steel VAV fume hoods (HT-FH-VAV) for organic solvents, general synthesis, and routine QC. Choose 100% metal-free virgin Polypropylene fume hoods (HT-FH-PP) whenever digesting samples with boiling nitric, hydrochloric, hydrofluoric (HF), or trace-metal ICP-MS acids that corrode metal fasteners.

Can lab benches, fume hoods, and cleanroom partitions ship together in one container?

Yes. We pre-assemble and factory-test all fume hood sashes/VAV valves, flat-pack C-frame steel cabinets and phenolic countertops on steel-strapped pallets, and load them alongside cleanroom panels and AHUs in consolidated 40'HQ containers.

Explore Related Cleanroom Systems & Specialized Hardware

Modular Hospital Laminar Operating Room EPC →Cytotoxic Safety Cabinets & USP 800 Isolators →GLP SPF Animal Vivarium & BSL-2/3 Lab EPC →Lithium & Solid-State Battery Dry Cleanroom (-65°C DP) →GMP Negative-Pressure Weighing & Sampling Booth →ISO 5 Laminar Flow Clean Bench & LAF Canopy →ASME BPE SUS316L Sanitary Process Piping & PW/WFI Loops →
Direct China Manufacturer · Grade-II EPC License D244805460 · ISO 9001 & CE

Request a 24-Hour Turnkey Cleanroom & Equipment BOQ

Looking for factory-direct pricing without middleman markups? Send our cleanroom HVAC and stainless equipment engineers your layout, target ISO 14644-1 class, or equipment list.

  • Stage-1 Budgetary Quote in 4–24 Hours: Itemized EXW / FOB Guangzhou / CIF / DDP unit pricing & container load plan.
  • Free Engineering Value-Add: AutoCAD room pressure cascade review, CFM/ACH air-change calculation & utility matrix.
  • Download Technical Dossiers: 6 A4 Engineering Spec Sheets (PDF) →
Direct Engineering Desk (Alex Gao):
Email: · WhatsApp:

Get Factory-Direct Pricing & CAD Support

No obligation · Direct response from senior cleanroom project engineer Alex Gao

By submitting you agree to our privacy policy; we use your details only to reply to this inquiry.

GMP QC Microbiology, Physicochemical Lab & VAV Fume Hood EPC Matrix

1:1 CAD-to-BIM turnkey R&D and QC analytical laboratories featuring phenolic Trespa/ceramic islands, CAV/VAV chemical fume hoods, and GC-MS specialty gas manifolds.

Cleanroom Class / SubsystemTarget Standard / CapacityHENGTAI Factory SpecificationPrimary Application
GMP Sterility & Micro QC LabGrade B Bench inside Grade C/D Suite3-Buffer Gowning + Pass Box + Biosafety HoodPharmacopoeia Sterility Test
Physicochemical & HPLC LabVAV Fume Hoods (0.5 m/s Face Velocity)Acid-Resistant PP Scrubber + Make-Up AirZero Solvent Fume Backdraft

Q: Do your VAV fume hoods automatically adjust room make-up air to hold negative pressure?

A (HENGTAI Chief Engineer): Yes. Sash-position sensors modulate exhaust VFD dampers in <1.5 seconds while tracking supply air valves to maintain constant -5 to -10 Pa room containment.