1:1 CAD-to-BIM-to-reality laboratory engineering: ISO 7/ISO 5 sterility & microbial limit suites, 0.50 m/s VAV fume hoods, Trespa island benches & exhaust scrubbers.
Guangzhou Hengtai (HENGTAI CLEAN · Grade-II EPC D244805460 & Decoration/Environmental Grade-II D344227631) delivers complete R&D formulation, QC physicochemical, HPLC/GC-MS analytical, and GMP microbiology clean laboratories—combining cleanroom zoning, 0.50 m/s Constant-Face-Velocity VAV Fume Hoods, 1.2 mm pickled-phosphated steel & PP polypropylene lab benches, high-purity specialty gas manifolds (N2, He, Ar, H2, Air), and roof wet-scrubber / activated-carbon exhaust treatment under one contract.

Pharmacopoeial Microbiology Zoning: Sterility Test Suite (ISO 7 / Grade B background + ISO 5 Laminar/Isolator, +15 Pa), Microbial Limit Suite (ISO 7, +10 Pa), and Positive Control / Pathogen Suite (Independent AHU, -10 Pa negative buffer—zero shared return air!). VAV Fume Hood Flow: Q_hood (m³/h) = W_sash × H_open × 0.50 m/s × 3,600 (ranging from 320 m³/h closed standby to 1,450 m³/h at 500 mm sash height with < 1.0 s Venturi/VAV damper tracking to hold room -5 Pa).
| Subsystem / Model | Applicable Standard | Dimensions & Core Material | Airflow / Containment Spec | Key Features | Engineering BOQ Basis |
|---|---|---|---|---|---|
| HT-LAB-MICRO (3-Suite Micro Lab Kit) | USP <1117> / ChP / EU GMP QC | 45–120 m² Modular ISO 7 + ISO 5 Suites | Independent AHUs for Sterility (+) vs Positive Control (-) | Flush Antibacterial Panels + Pass Boxes + Interlocks | Custom BOM Quote (24h Itemized BOQ) |
| HT-LAB-PCR (4-Room Molecular PCR Lab) | WHO Molecular Diagnostics | Reagent (+10 Pa) → Specimen (-5 Pa) → Amp (-15 Pa) → Product (-25 Pa) | 100% Unidirectional Workflow + Pass-Box UV Interlocks | Zero Amplicon Back-Diffusion Pressure Cascade | Custom BOM Quote (24h Itemized BOQ) |
| HT-FH-1500-VAV (Steel VAV Fume Hood) | ASHRAE 110 / EN 14175 | 1500 × 850 × 2350 mm (1200 / 1800 opt.) | 0.50 m/s ±10% Constant Face Velocity · Sash Displacement Sensor | Epoxy Steel + Ceramic Worktop + Phenolic Liner | Custom BOM Quote (24h Itemized BOQ) |
| HT-FH-1500-PP (Acid-Proof PP Fume Hood) | Trace Metal / HF / Perchloric | 1500 × 850 × 2350 mm · 8–12 mm Virgin PP | 0% Metal Interior · Optional Built-in Mist Washdown | Seamless Welded Polypropylene for Strong Acids | Custom BOM Quote (24h Itemized BOQ) |
| HT-BENCH-C (Island & Wall Lab Benches) | SEFA 8M Load Rated (≥ 300 kg/m²) | W 750/1500 × H 850 mm Modular Lengths | 12.7 mm Solid Phenolic (Trespa) / 20 mm Epoxy Resin Top | 60×40×1.5mm C-Frame Steel + Reagent Rack + PP Sinks | Custom BOM Quote (24h Itemized BOQ) |
Delivered for listed cosmetics & biopharma leaders including PROYA and Befe.: curved floor-to-ceiling tempered vision walls, concealed GC/ICP-MS stainless atomic absorption exhaust canopies, and ergonomic island benches.
Traditional CAV fume hoods exhaust 1,500 m³/h of conditioned 22°C lab air 24/7 even when nobody stands in front. Our ultrasonic sash-height VAV controllers + room differential pressure makeup tracking cut conditioned makeup air energy by up to 68%.
Complete environmental compliance (License D344227631): NaOH alkaline spray packed-bed towers neutralize HCl/HNO3/H2SO4 inorganic acid fumes while multi-bed honeycomb activated carbon adsorbs VOC solvent vapors.
91440101MA59M8NW4E · Building EPC Grade-II D244805460 · Decoration/Steel/Environmental Grade-II D344227631 · Safety License GD-JZ [2022]010947.GR202444009466 · ISO 9001:2015 90924Q00571R0M · CE & EAC · 63 National Patents & 19 Software Copyrights.
Never. Sharing return ductwork between the Positive Control room (where live Staphylococcus aureus, Pseudomonas aeruginosa, and Candida albicans reference strains are inoculated) and the Sterility Test suite creates false-positive batch failures and immediate GMP critical observations. We supply dedicated compact hygienic AHUs for each zone.
Choose epoxy-coated steel VAV fume hoods (HT-FH-VAV) for organic solvents, general synthesis, and routine QC. Choose 100% metal-free virgin Polypropylene fume hoods (HT-FH-PP) whenever digesting samples with boiling nitric, hydrochloric, hydrofluoric (HF), or trace-metal ICP-MS acids that corrode metal fasteners.
Yes. We pre-assemble and factory-test all fume hood sashes/VAV valves, flat-pack C-frame steel cabinets and phenolic countertops on steel-strapped pallets, and load them alongside cleanroom panels and AHUs in consolidated 40'HQ containers.
Looking for factory-direct pricing without middleman markups? Send our cleanroom HVAC and stainless equipment engineers your layout, target ISO 14644-1 class, or equipment list.
1:1 CAD-to-BIM turnkey R&D and QC analytical laboratories featuring phenolic Trespa/ceramic islands, CAV/VAV chemical fume hoods, and GC-MS specialty gas manifolds.
| Cleanroom Class / Subsystem | Target Standard / Capacity | HENGTAI Factory Specification | Primary Application |
|---|---|---|---|
| GMP Sterility & Micro QC Lab | Grade B Bench inside Grade C/D Suite | 3-Buffer Gowning + Pass Box + Biosafety Hood | Pharmacopoeia Sterility Test |
| Physicochemical & HPLC Lab | VAV Fume Hoods (0.5 m/s Face Velocity) | Acid-Resistant PP Scrubber + Make-Up Air | Zero Solvent Fume Backdraft |
A (HENGTAI Chief Engineer): Yes. Sash-position sensors modulate exhaust VFD dampers in <1.5 seconds while tracking supply air valves to maintain constant -5 to -10 Pa room containment.