GUANGZHOU HENGTAI HIGH-TECH GROUP (HENGTAI CLEAN · HENGTAI DECORATION) · RMB 38,000,000 CAPITAL · GRADE-II EPC CONTRACTOR D244805460
✉ · · 1v1 Comparisons · Technical Specs · PDF Licenses
HOME / 1V1 COMPARISONS / VHP VS DYNAMIC VS STATIC PASS BOX

Cleanroom Material Transfer Comparison: VHP Bio-Decontamination Pass Box vs. Dynamic Laminar vs. Static UV Pass Box

By Mr. Tan Shuping (30+ Year GMP Chief Engineer), Mr. Liu Wei (Chief Architect) & Alex Gao · Updated 2026-11-09 · Verified against D244805460 / D344227631 Grade-II EPC & 26,000 m² Factory Standards

Buyer Pain Point Solved: EU GMP Annex 1 (2023/2026) inspectors issue critical observations when factories use simple static UV pass boxes to transfer materials across Grade C/D into Grade B/A sterile zones.
Hengtai Decoration & HENGTAI CLEAN Factory-Direct Solution: HENGTAI CLEAN manufactures all 3 tiers of SUS304/SUS316L cleanroom pass boxes: Static Electromagnetic Interlocked (between equal classes), Dynamic Self-Purifying Laminar Flow (ISO 5 internal wash), and VHP Vaporized Hydrogen Peroxide Bio-Decontamination Pass Chambers (6-log biological indicator kill).

1. 3-Tier Cleanroom Pass Box Engineering & Regulatory Selection Matrix

SpecificationVHP Bio-Decontamination Pass Box (HT-PB-VHP)Dynamic Laminar Flow Pass Box (HT-PB-DYN)Static UV Interlocked Pass Box (HT-PB-STA)
Target Regulatory ApplicationGrade C/D → Grade B/A Sterile Transfer (EU GMP Annex 1 / BSL-3)Unclassified / ISO 8 → ISO 7 / Grade C TransferEqual Class Transfer (e.g., ISO 8 → ISO 8)
Decontamination Mechanism35% Flash-Vaporized H2O2 (6-Log Spore Reduction) + Catalytic Aeration (<1 ppm)0.45 m/s Vertical H14 Laminar Flow (ISO Class 5 Internal Recirculation)254nm UV-C Germicidal Lamp (Surface shadow limitation)
Chamber Material & Door Seal2.0mm SUS316L Mirrorless + Pneumatic Inflatable Silicone Seal1.5mm SUS304 + Flush Double-Glazed Tempered Glass Door1.2mm/1.5mm SUS304 + Mechanical/Magnetic Interlock
Validation & InstrumentationSiemens PLC + 21 CFR Part 11 Audit Trail + PAO Port + H2O2 High/Low SensorsDwyer Magnehelic 0–500 Pa Gauge + DOP/PAO Injection Port + Adjustable TimerDigital Interlock Indicator + UV Hour Counter
Factory-Direct FOB Price (600×600×600 mm)Custom BOM Quote (24h Itemized BOQ)Custom BOM Quote (24h Itemized BOQ)Custom BOM Quote (24h Itemized BOQ)

Complete 2026 Cleanroom & Purification 1v1 Engineering Comparison Matrix

1. HENGTAI CLEAN vs Terra Universal vs Mecart vs Connect 2 Cleanrooms
1×40'HQ Pre-Engineered Modular Cleanroom Kit Cost, Lead Time & Grade-II EPC Comparison
2. Rockwool vs MgO vs Aluminum Honeycomb vs PIR Sandwich Panels
50mm/75mm/100mm Class A1 Fire Rating, Walk-On Ceiling Deflection & Moisture Resistance
3. Modular Hardwall Sandwich Panel Cleanroom vs Traditional Drywall Stud
12-Day Bolted Fit-Out, Zero Dust, Tax Depreciation & 90% Panel Reusability
4. Knock-Down (KD) Flat-Pack vs Fully Welded Monoblock SUS304 Air Shower
65% Ocean Freight Saving, 800mm Door Rigging Access & 25–28 m/s Nozzle Velocity
5. EC Brushless Modbus FFU vs AC FFU & Liquid Gel-Seal H14 vs Gasket HEPA
42% HVAC Energy Reduction, 10,000-Unit RS485 Control & Camfil/AAF/MayAir Benchmark
6. VHP Sterilization Pass Box vs Dynamic Laminar vs Static UV Pass Box
6-Log Spore Reduction for EU GMP Annex 1 Grade A/B vs Class 7/8 Buffer Transfer
7. PSA Oxygen-Fed Water-Cooled Ozone vs Air-Fed Ozone vs Chemical CIP
80–120 mg/L Concentration, Zero Chlorate/THM Residue & 24/7 Continuous Operation
8. Dual-Stage Desiccant Rotor Dehumidifier AHU vs Standard DX/Chilled Coil
-40°C to -60°C Dew Point Dry Room (Lithium Battery) & <20% RH Effervescent/Softgel Suite

2. Frequently Asked Engineering & Procurement Questions (FAQ)

Q: Why does EU GMP Annex 1 restrict UV-only pass boxes when transferring materials between different cleanliness grades?

A (Chief Engineer Tan Shuping · Grade-II EPC D244805460): UV-C light cannot penetrate shaded underside surfaces or folds of Tyvek bags and provides no active airborne particle scavenging when the outer door opens. Annex 1 requires active HEPA-filtered laminar flushing (Dynamic Pass Box) or validated sporicidal gas bio-decontamination (VHP Pass Box).

Q: How long is a complete VHP pass box cycle including aeration to <1 ppm H2O2?

A (Chief Engineer Tan Shuping · Grade-II EPC D244805460): Depending on chamber load, dehumidification + conditioning + 6-log sterilization + catalytic aeration takes 35–55 minutes with zero external duct exhaust required when fitted with our platinum catalytic converter.

Direct China Manufacturer · Grade-II EPC License D244805460 · ISO 9001 & CE

Request a 24-Hour Turnkey Cleanroom & Equipment BOQ

Looking for factory-direct pricing without middleman markups? Send our cleanroom HVAC and stainless equipment engineers your layout, target ISO 14644-1 class, or equipment list.

  • Stage-1 Budgetary Quote in 4–24 Hours: Itemized EXW / FOB Guangzhou / CIF / DDP unit pricing & container load plan.
  • Free Engineering Value-Add: AutoCAD room pressure cascade review, CFM/ACH air-change calculation & utility matrix.
  • Download Technical Dossiers: 6 A4 Engineering Spec Sheets (PDF) →
Direct Engineering Desk (Alex Gao):
Email: · WhatsApp:

Get Factory-Direct Pricing & CAD Support

No obligation · Direct response from senior cleanroom project engineer Alex Gao

By submitting you agree to our privacy policy; we use your details only to reply to this inquiry.