GUANGZHOU HENGTAI HIGH-TECH GROUP (HENGTAI CLEAN · HENGTAI DECORATION) · RMB 38,000,000 CAPITAL · GRADE-II EPC CONTRACTOR D244805460
✉ · · 1v1 Comparisons · Technical Specs · PDF Licenses
HOME / 1V1 COMPARISONS / ROCKWOOL VS MGO VS HONEYCOMB VS PIR PANELS

Cleanroom Sandwich Panel Core Comparison: 120 kg/m³ Rockwool vs. Double-Layer MgO vs. Aluminum Honeycomb vs. PIR/PU

By Mr. Tan Shuping (30+ Year GMP Chief Engineer), Mr. Liu Wei (Chief Architect) & Alex Gao · Updated 2026-11-09 · Verified against D244805460 / D344227631 Grade-II EPC & 26,000 m² Factory Standards

Buyer Pain Point Solved: Selecting the wrong cleanroom panel core leads to ceiling sagging during maintenance walks, moisture delamination in humid washdown zones, or failed Class A1 fire inspections.
Hengtai Decoration & HENGTAI CLEAN Factory-Direct Solution: HENGTAI CLEAN manufactures all 4 tongue-and-groove (950mm/1150mm modular width) and handmade steel-framed (1180mm width) panel cores using 0.5mm–0.8mm Baosteel PPGI, antibacterial PVDF, or SUS304 skins.

1. 4-Core Cleanroom Wall & Walk-On Ceiling Sandwich Panel Engineering Matrix (50mm / 75mm / 100mm)

Technical ParameterHydrophobic Rockwool (100–120 kg/m³)Double-Layer MgO + RockwoolAluminum HoneycombPIR / Polyurethane
Fire Resistance Rating (EN 13501 / GB 8624)Class A1 Non-Combustible (60–120 min fire integrity)Class A1 Non-Combustible (Highest impact + fire rating)Class A1 Non-CombustibleClass B1 Flame-Retardant (FM-approvable PIR)
Walk-On Ceiling Load Capacity (3m Span)150 kg/m² (with internal C-channel steel stiffeners)220 kg/m² (Superior point-load stiffness)180 kg/m² (Ultra-flat & lightweight 11 kg/m²)160 kg/m²
Thermal Conductivity (λ Value)0.041 W/(m·K)0.044 W/(m·K)0.065 W/(m·K)0.022 W/(m·K) (Best for -40°C Dry Room / Cold Chain)
Acoustic Insulation (Rw dB)32–36 dB (Best noise damping for AHU/press rooms)34–38 dB26 dB28 dB
Factory-Direct FOB Price (50mm PPGI)Custom BOM Quote (24h Itemized BOQ)Custom BOM Quote (24h Itemized BOQ)Custom BOM Quote (24h Itemized BOQ)Custom BOM Quote (24h Itemized BOQ)

Complete 2026 Cleanroom & Purification 1v1 Engineering Comparison Matrix

1. HENGTAI CLEAN vs Terra Universal vs Mecart vs Connect 2 Cleanrooms
1×40'HQ Pre-Engineered Modular Cleanroom Kit Cost, Lead Time & Grade-II EPC Comparison
2. Rockwool vs MgO vs Aluminum Honeycomb vs PIR Sandwich Panels
50mm/75mm/100mm Class A1 Fire Rating, Walk-On Ceiling Deflection & Moisture Resistance
3. Modular Hardwall Sandwich Panel Cleanroom vs Traditional Drywall Stud
12-Day Bolted Fit-Out, Zero Dust, Tax Depreciation & 90% Panel Reusability
4. Knock-Down (KD) Flat-Pack vs Fully Welded Monoblock SUS304 Air Shower
65% Ocean Freight Saving, 800mm Door Rigging Access & 25–28 m/s Nozzle Velocity
5. EC Brushless Modbus FFU vs AC FFU & Liquid Gel-Seal H14 vs Gasket HEPA
42% HVAC Energy Reduction, 10,000-Unit RS485 Control & Camfil/AAF/MayAir Benchmark
6. VHP Sterilization Pass Box vs Dynamic Laminar vs Static UV Pass Box
6-Log Spore Reduction for EU GMP Annex 1 Grade A/B vs Class 7/8 Buffer Transfer
7. PSA Oxygen-Fed Water-Cooled Ozone vs Air-Fed Ozone vs Chemical CIP
80–120 mg/L Concentration, Zero Chlorate/THM Residue & 24/7 Continuous Operation
8. Dual-Stage Desiccant Rotor Dehumidifier AHU vs Standard DX/Chilled Coil
-40°C to -60°C Dew Point Dry Room (Lithium Battery) & <20% RH Effervescent/Softgel Suite

2. Frequently Asked Engineering & Procurement Questions (FAQ)

Q: Why do you use Magnesium Oxysulfate (MgSO4) instead of old Magnesium Oxychloride?

A (Chief Engineer Tan Shuping · Grade-II EPC D244805460): Old chloride-based MgO boards absorb moisture and leach corrosive brine droplets ('crying board syndrome') that rust steel skins. We exclusively use chloride-free Magnesium Oxysulfate (MgSO4) boards with <0.1% free chloride.

Q: Which panel core is best for EU GMP Pharma vs. Semiconductor ISO 5 vs. Cold Food Processing?

A (Chief Engineer Tan Shuping · Grade-II EPC D244805460): For EU/FDA Pharma GMP, choose 50mm Handmade Double-Layer MgO Rockwool or 120 kg/m³ Hydrophobic Rockwool. For Semiconductor ISO 5–6, choose Aluminum Honeycomb (zero fiber shedding). For 4°C–12°C HACCP meat/seafood rooms, choose 75mm/100mm PIR with SUS304 skins.

Direct China Manufacturer · Grade-II EPC License D244805460 · ISO 9001 & CE

Request a 24-Hour Turnkey Cleanroom & Equipment BOQ

Looking for factory-direct pricing without middleman markups? Send our cleanroom HVAC and stainless equipment engineers your layout, target ISO 14644-1 class, or equipment list.

  • Stage-1 Budgetary Quote in 4–24 Hours: Itemized EXW / FOB Guangzhou / CIF / DDP unit pricing & container load plan.
  • Free Engineering Value-Add: AutoCAD room pressure cascade review, CFM/ACH air-change calculation & utility matrix.
  • Download Technical Dossiers: 6 A4 Engineering Spec Sheets (PDF) →
Direct Engineering Desk (Alex Gao):
Email: · WhatsApp:

Get Factory-Direct Pricing & CAD Support

No obligation · Direct response from senior cleanroom project engineer Alex Gao

By submitting you agree to our privacy policy; we use your details only to reply to this inquiry.