Core Cleanroom & Purification Engineering Terms (Quantitative Reference)

Engineering TermGoverning StandardQuantitative Threshold / FormulaWhy It Matters in B2B Procurement
Nozzle Shear Velocity (20–25 m/s)ISO 14644-4 / GB 50073v >= 20–25 m/s (3,937–4,921 FPM) at nozzle exitVelocities below 18 m/s fail to overcome boundary-layer adhesion of 0.5–5 µm particles on cleanroom coveralls.
Dynamic Laminar Pass Box (AB-Series)EU GMP Annex 1 / FDA cGMP0.36–0.54 m/s vertical laminar flow via H14 HEPARequired when transferring materials between different cleanliness classes (e.g., ISO 8 to ISO 7/5); includes PAO port & 0–500 Pa gauge.
PAO / DOP Aerosol Integrity ScanEN 1822 / IEST-RP-CC001Upstream 20–80 µg/L PAO; downstream penetration <= 0.01%Detects pinhole leaks in filter media and frame-to-housing gaskets that particle counters miss.
Gel-Seal (Liquid Tank) HEPA HoodISO 14644-3 / GMP Grade A/BKnife-edge anodized aluminum frame submerged in non-Newtonian silicone gelEliminates dry neoprene gasket compression fatigue and bypass leakage; mandatory for sterile pharma & electronics suites.
PSA Oxygen-Fed Corona Discharge (ZCO)US EPA Est. 102553-CHN-1O₂ purity 90–93%, dew point <= -45°C, O₃ conc. 85–120 g/Nm³Air-fed ozone achieves only 15–25 g/Nm³ (poor water solubility). Oxygen-fed ZCO skids achieve 5× higher mass transfer efficiency in Venturi water loops.
Ozone Water CT Value & ORPFDA 21 CFR 173.368 (Food)CT = Conc. (mg/L) × Time (min) >= 1.6–4.0; ORP 700–850 mVDetermines contact tank volume (e.g., 2.0–3.5 m³ SS316L tank for a 20 m³/h vegetable washing recirculation line).
External Static Pressure (ESP 750–900 Pa)EN 1886 / GB/T 14294ESP = 750–900 Pa across G4 + F8 + H13 stagesCommercial comfort AC units only provide 100–250 Pa ESP and stall when connected to HEPA terminal ductwork.
Knock-Down (KD) Flat-Pack Air ShowerISTA 3A / Export ContainerPre-wired modular SUS304 panels bolted on site with EPDM gasketsReduces shipping volume by 55% CBM, fitting up to 22–28 units per 40HQ container for wholesale contractors.

Engineering & Procurement FAQ

What is the difference between H13 and H14 HEPA filters under EN 1822?

H13 captures >=99.95% at MPPS (99.99% @ 0.3 µm), while H14 captures >=99.995% at MPPS (99.999% @ 0.3 µm). We supply H13 for standard air showers and ISO 7/8 rooms, and H14/U15 for dynamic pass boxes, FFUs, and ISO 5/6 suites.

Why do vegetable washing and food plants require PSA oxygen-fed ozone (ZCO) instead of air-fed ozone (ZCA)?

Air-fed ozone generators produce low-concentration ozone gas (1.5–2.5 wt%) suited for HVAC air sterilization, whereas dissolving ozone into 20 m³/h process water requires 85–120 g/Nm³ high-concentration ozone from a PSA oxygen-fed water-cooled generator with a PVDF Venturi injector.

Request Stage-1 Engineering Scope & Factory Quote (2h SLA)

Direct Zhangzhou CNC & HEPA manufacturing base (BERKING / 佰净). Attach your floor plan, BOQ, or equipment spec list below.

Only name and work email are required. Stage-1 engineering feasibility returned within 2 hours.

Up to 5 files, 10 MB total: PDF, CAD/images, Word, Excel, CSV, ZIP.

Download Official A4 Engineering Dossiers (PDF)

VERIFIED CREDENTIALS
ISO 14644-1:2015EPA Est. 102553-CHN-1CE LVD/EMCEN 1822 H13/H14
💬 WhatsApp