Hengtai Decoration & HENGTAI CLEAN Factory-Direct Solution: HENGTAI CLEAN manufactures 2.0mm–3.0mm TIG-welded SUS316L VHP Bio-Decontamination Pass Chambers with built-in flash vaporizers, platinum catalytic converters, and FDA 21 CFR Part 11 Siemens PLC controls, alongside pneumatic inflatable-seal biosafety doors.
1. VHP Bio-Decontamination Pass Box Standard Models & Performance Parameters
| Model Code | Internal Chamber (W×D×H mm) | External Size (W×D×H mm) | VHP Generator & Cycle Time | Aeration & Filtration | FOB Price |
|---|---|---|---|---|---|
| HT-VHP-PB600 | 600 × 600 × 600 mm | 960 × 780 × 1750 mm | Integrated Flash Vaporizer (35% H2O2) · 35–45 min total cycle | Dual H14 Gel-Seal HEPA + Pt Catalytic Breakdown (<1 ppm) | Custom BOM Quote (24h Itemized BOQ) |
| HT-VHP-PB800 | 800 × 800 × 800 mm | 1160 × 980 × 1950 mm | Peristaltic Precision Pump (0.5–5 g/min) · 40–50 min cycle | High- & Low-Range H2O2 Electrochemical Sensors (0–2000 / 0–10 ppm) | Custom BOM Quote (24h Itemized BOQ) |
| HT-VHP-CART1200 | 1000 × 1000 × 1200 mm (Floor Trolley) | 1400 × 1180 × 2250 mm | Dual-Fan Laminar Distribution + Dehumidification Loop | Siemens S7-1200 PLC + 7" HMI + Audit Trail Printer + PAO Port | Custom BOM Quote (24h Itemized BOQ) |
| HT-DOOR-INF316 | 900 × 2100 mm / 1200 × 2100 mm Clear | Flush 50mm/100mm Wall Frame | Pneumatic EPDM/Silicone Inflatable Perimeter Gasket (0.25 MPa) | Passes ±500 Pa Pressure Decay Test (<0.05 m³/h leakage) | Custom BOM Quote (24h Itemized BOQ) |
Complete 2026 Cleanroom EPC, Envelope & Equipment Specification Library
0.45 m/s Unidirectional Laminar Flow, +15 Pa Cascades, CCS & VHP Integration 2. USP <797> & USP <800> Compounding Pharmacy Modular Cleanroom Kit
-2.5 to -7.5 Pa Hazardous Drug C-SEC Negative Pressure, 30 ACH & Ante-Room 3. ISO 22716 & US FDA MoCRA Class 100,000 Cosmetic GMPC Cleanroom Spec
Emulsifying Hall, RO+EDI Water Loop, VIP Visiting Corridor & 1×40'HQ Kit 4. 50mm / 75mm / 100mm Cleanroom Sandwich Panel, Flush Window & Door Spec
120 kg/m³ Rockwool, Double MgO, Al-Honeycomb, R50 Coving & Drop-Seal Doors 5. SUS316L VHP Sterilization Pass Box & Inflatable-Seal Airtight Door Spec
6-Log Spore Kill, <1 ppm H2O2 Catalytic Breakdown & 21 CFR Part 11 PLC 6. Tool-Free SUS304 Automated Boot Washer & Turnstile Hygiene Station Spec
HACCP/BRCGS Listeria Control: Sole/Boot Brush + Soap + Wash + Dryer + Turnstile 7. Commercial 10–30 g/h Portable Ozone & 100–500 g/h PSA Ozone Skid Spec
HT-10/20/30 Hotel/Detailer/Cold-Room Deodorizer & HT-100..500 Dissolved Water Skid 8. EN 1886 Hygienic Cleanroom AHU / ACMV & Constant Temp/Humidity Spec
50mm Thermal-Break Casing, SUS304 Drain Pan, G4+F8+H13 & ±0.5°C / ±3% RH PLC
2. Frequently Asked Engineering & Procurement Questions (FAQ)
Q: How is the door sealed during the VHP gassing phase to guarantee zero H2O2 leakage into the operator room?
A (Chief Engineer Tan Shuping · Grade-II EPC D244805460): Both doors utilize compressed-air inflatable medical-grade silicone perimeter gaskets (inflated to 0.20–0.25 MPa before H2O2 injection) monitored by continuous pressure switches. The doors cannot deflate or unlock until the low-range H2O2 sensor confirms chamber concentration is <1.0 ppm.
Q: Do you provide Biological Indicator (BI) validation mapping reports before shipment?
A (Chief Engineer Tan Shuping · Grade-II EPC D244805460): Yes. Every VHP pass box undergoes a 10-point Geobacillus stearothermophilus (10^6 spores) distribution challenge test and pressure-decay test during Factory Acceptance Testing (FAT).