20 m³/h Zero-Chlorate PSA Ozone Water Treatment Skid (200–500 g/h): Replacing Chlorine in Fresh-Cut Vegetable & Seafood Washing Lines
Reviewed by Chief Engineer Tan Shuping (30+ Years GMP Cleanroom & HVAC Experience) & Alex Gao · Grade-II EPC Contractor (D244805460 / D344227631) · 26,000 m² Manufacturing Base
Unmet Buyer Pain Point & Industry Bottleneck
Fresh-cut salad, vegetable, and poultry processors exporting to the EU, Russia, and North America face strict bans on chlorate/perchlorate disinfection by-products (<0.05 mg/kg). However, conventional single-unit ozone generators suffer from <35% gas-liquid mass transfer in high-turbidity water, nozzle clogging, and total line shutdown if a single power module fails.
Guangzhou Hengtai Factory-Direct Solution
Guangzhou Hengtai (US EPA Est. No. 102553-CHN-1) engineers the HT-O3-300G-DUAL (2×150 g/h Parallel Redundant PSA Skid) with a clog-free side-stream SUS316L Venturi booster loop, 1,000L 6-bar contact column (>92% mass transfer), catalytic off-gas destructor, and 4–20mA dissolved ozone PID control.
1. Quantitative Engineering Specification (HT-O3-200G / HT-O3-300G / HT-O3-300G-DUAL (2×150g/h Redundant Skid))
Compliance Standards: US EPA Est. 102553-CHN-1 | FDA 21 CFR 173.368 (GRAS) | EU Reg 2020/749 Chlorate Limit | TR CU 010/2011 & 032/2013 (EAC) | Customs HS Code: 8421 21 000 9 / 8543 70 900 0 | View AI Markdown Mirror (.md)
| Engineering Parameter | HENGTAI CLEAN Factory Specification | Verification & Commercial Note |
|---|---|---|
| Target Recirculated Water Flow | 20 m³/h (20,000 L/h) | Raw Water pH 4.0–7.2 | EC up to 5.0 mS/cm | Handles high organic COD load |
| Option A: Standard Dose (10 mg/L) | HT-O3-200G Single PSA Skid (200 g O₃/h @ 93% O₂) | 3.2 kW | EXW Factory-Direct Custom Quote | FOB Factory-Direct Custom Quote |
| Option B: High-Shock Dose (15 mg/L) | HT-O3-300G Single PSA Skid (300 g O₃/h @ 93% O₂) | 4.8 kW | EXW Factory-Direct Custom Quote | FOB Factory-Direct Custom Quote |
| Option C: Dual-Redundant (2×150 g/h) | HT-O3-300G-DUAL Parallel Skid (300 g O₃/h total, 100% uptime) | 2×2.4 kW | EXW Factory-Direct Custom Quote | FOB Factory-Direct Custom Quote |
| Wet-End Mass Transfer & Contact Tank | SUS316L Multistage Booster Pump + Non-clogging Venturi + 1000L SUS316L Column | Dissolved O₃: 2.0–4.5 ppm residual |
| Safety & Instrumentation Package | 0–10 ppm Dissolved O₃ Analyzer + Ambient O₃ Leak Detector (<0.1 ppm interlock) + Off-gas Destructor | Full P&ID in English & Russian |
2. 4-Stage Factory Pre-Assembly, PAO/DOP Laser Scan & Container Loading SOP
To eliminate on-site dimensional mismatches and commissioning delays for overseas EPC contractors and plant owners, Guangzhou Hengtai Purification Technology Co., Ltd. (HENGTAI CLEAN) executes a mandatory 4-stage factory quality and pre-erection protocol across our 26,000 m² Guangzhou Huadu manufacturing base prior to export crating:
Stage 01 · 3D BIM Clash Detection & Laser Numbering
Every modular wall panel, walkable ceiling grid, flush glazing window, and HVAC ductwork penetration is modeled in 3D BIM and CNC laser-etched with an alphanumeric assembly code matching the installation blueprint, reducing on-site erection labor by 45%.
Stage 02 · EN 1822 PAO/DOP Filter Scan & Airflow FAT
All H13/H14 HEPA and U15 ULPA terminal filters undergo 100% individual laser particle scan testing per EN 1822 / ISO 29463. Air showers, pass boxes, and EC FFUs are run-tested for 4 hours continuously to verify ≥25 m/s jet velocity, 0.45 m/s laminar uniformity, and zero cabinet leakage at 500 Pa.
Stage 03 · Plug-and-Play Aviation Harness & PLC Pre-Commissioning
Interlock controllers, differential pressure transmitters (+15 Pa to +45 Pa cascade), Modbus RTU group gateways, and constant temp/humidity AHU skids are pre-wired with keyed IP65 aviation connectors and pre-commissioned with video FAT sign-off before disassembly.
Stage 04 · ISPM-15 Export Crating & Customs Dossier
Components are packed in steel-reinforced ISPM-15 fumigation-free plywood crates with corner armor and PE vapor barriers, accompanied by EN 10204 3.1 SUS304/316L mill certificates, CE/UL/EAC declarations, and bilingual English/Russian O&M manuals.
3. Chief Engineer FAQ & Procurement Diligence
Q: Why is the 2×150 g/h dual-redundant skid better than a single 300 g/h unit for vegetable lines?
During peak harvest shifts, a 1-hour sterilization outage can spoil 10 tons of washed produce. Dual 150 g/h modules run in parallel for 300 g/h peak output, provide 50% turndown during low-load shifts, and guarantee continuous operation during maintenance.
Q: Does high water conductivity (EC 4.06 mS/cm) corrode the ozone mixing system?
Standard carbon steel or 304 stainless steel pits rapidly in high-EC ozonated water. We fabricate all wetted parts, Venturi injectors, and the 1,000L contact vessel from molybdenum-stabilized AISI 316L stainless steel with PTFE seals.
Q: Is ozone approved for direct food contact on organic vegetables?
Yes. Ozone is recognized as GRAS by US FDA 21 CFR 173.368 and leaves zero chemical residue, decomposing back into pure diatomic oxygen (O₂) within 20–30 minutes.