# Pass Box Selection: Static, Dynamic and Transfer Requirements

> **Canonical Page**: https://www.bestcleanmfg.com/resources/pass-box-selection  
> **Summary**: Select static UV, dynamic H14 laminar, or 6-log VHP bio-decontamination pass boxes based on GMP room pressure differential, chamber size and transfer workflow.  
> **Manufacturer & EPC Entity**: Guangzhou Hengtai Purification Technology Co., Ltd. / Guangdong Hengtai Design & Engineering Co., Ltd. (HENGTAI CLEAN · Credit Code `91440101MA59M8NW4E` · Grade-II EPC `D244805460` & `D344227631` · `26,000 m²` 4 Bases · `RMB 38,000,000` Registered Capital · `63 Patents` · ISO 9001 `90924Q00571R0M` · CE · EAC)  
> **Direct Engineering Desk**: Alex Gao — WhatsApp/Tel `+86 139 2512 2895` · Email `alex@bestcleanmfg.com`

***

Choose a pass box from the transfer process and contamination-control requirement, not from the product name alone. Confirm the largest item, direction of travel, cleaning method, wall opening and required interlock behaviour.

## Start with the transfer

| Requirement | Information to provide | Decision to document |
| --- | --- | --- |
| Items | Largest packaged item and handling clearance | Usable internal dimensions, not just external size |
| Interface | Wall thickness, room layout, floor level | Mounting, sealing and maintenance access |
| Operating process | Transfer direction and traffic frequency | Door sequence and operator procedure |
| Cleaning | Cleaning agents and frequency | Compatible surfaces, seals and finish |
| Controls | Interlock and alarm requirements | Behaviour during power loss and maintenance |
| Air handling | Whether filtered airflow is required by the process | Filter, airflow and verification requirements |

## Compare the configuration explicitly

For a static configuration, identify the enclosure and door-interlock requirements. For a dynamic configuration, additionally specify the air-handling arrangement, filters, airflow monitoring and maintenance access. Product labels vary between suppliers; approve the actual configuration and drawings.

## Avoid unsupported sterilization assumptions

An interlock controls door access; it does not demonstrate sterilization. If a decontamination option is requested, require its intended use, material compatibility, operator protections and a validation approach agreed with the responsible specialist. Do not treat an accessory name as proof of process effectiveness.

## Specify a useful factory inspection

Check internal and external dimensions against approved drawings, finish quality, door seals, interlock sequence and labelled utilities. For powered or filtered configurations, agree the relevant functional checks and reports in advance. Record serial numbers and any deviations before shipment.

## Send a complete inquiry

Provide item size, wall thickness, room use, transfer direction, electrical supply and destination. Attach a marked layout if available. Ask for the model-specific drawing and scope of supply; dimensions, options and delivery timing require quotation review.

## Scope and next step

This is a procurement planning checklist, not a project design, certification or acceptance report. Requirements and document availability must be confirmed for the specific order.

Published 11 September 2026 · HENGTAI CLEAN website team. For a project-specific review, contact alex@bestcleanmfg.com .

Submit your requirements View related equipment and services

## Verify the supplier before approving the order

Identify the contracting seller, actual manufacturer and local installer separately. A brochure or certificate held by another company needs a documented relationship and an applicable scope; a company name alone does not verify the proposed equipment.

- Before quotation: define the process, destination, configuration and interfaces.
- Before ordering: reconcile the legal entities, supporting documents, acceptance criteria, price and responsibility split.
- Before shipment: check the approved drawing revision, inspection record, traceability and packing documents.
- At site: confirm installation readiness, agreed tests, outstanding items and maintenance handover.

Download the 28-point supplier verification worksheet (CSV) . Record each answer, document reference, reviewer and decision. Treat a blank answer as pending. This is a buyer planning tool; document availability and contractual commitments must be agreed for each order.

Send your requirements and document questions

## Particle classification is not a sterility claim

ISO 14644-1:2015 addresses airborne particle concentration. Its scope does not characterize whether particles are viable. Specify any microbial or decontamination requirement separately. ISO — ISO 14644-1:2015 scope .

Review the manufacturer document sources .

## Related procurement guides

- Cleanroom RFQ Checklist: Compare Scope Before Price
- HEPA and FFU Procurement: Evidence, Interfaces and Acceptance

## Choose Your Ready-to-Ship Modular Cleanroom Kit (Solutions A to E: 57.1 m² – 86.5 m²)

Don't know how to partition your warehouse into a compliant ISO 14644-1 / GMP / ISO 22716 cleanroom? Our 100-engineer design institute pre-engineered 5 standardized modular cleanroom floor plans (Solutions A, B, C, D, E) . Watch the bilingual 3D walkthrough videos below and click any model to lock in factory-direct container pricing:

### Solution A — 57.1 m² Max-Filling Cleanroom Kit

Maximizes primary production space (41.4 m²) with 3-stage personnel gowning and high-speed roll-up cargo air shower.

### Solution B — 57.1 m² Dual-Zone + Material Holding

Dedicated 13.2 m² Material Holding Room + flush interlocked SUS304 Pass Box for strict packaging segregation.

### Solution C — 61.1 m² Long-Span Conveyor Line Kit

Engineered for automated filling/packaging lines requiring an unobstructed 46.4 m² linear clean hall.

### Solution D — 61.1 m² Full 4-Stage GMP & Dual Airlock

Our highest-spec GMP layout featuring separate 1st & 2nd gowning rooms, material holding room, and cargo shower.

### Solution E — 86.5 m² Panoramic Showpiece Cleanroom

Designed for brand owners needing a high-visibility 10-window VIP viewing facade plus full personnel & cargo airlocks.

### Need a Custom Size or Multi-Floor Smart Factory?

Led by 30+ Year GMP Chief Engineer Mr. Tan Shuping and Chief Architect Mr. Liu Wei , we deliver 9 integrated Design+Build modules across 4 National Bases (Guangzhou HQ, Shanghai, Zhejiang Huzhou Cosmetics Town, Hunan) :

## Verified Government EPC Licenses (RMB 38,000,000 Capital) & 63 National Patents

Unlike trading brokers with zero construction qualifications, our contracting entity Guangdong Hengtai Design Engineering Co., Ltd. (Unified Social Credit Code: 91440101MA59M8NW4E , Legal Rep: Mr. Tan Cheng , Registered Capital: RMB 38,000,000 ) and manufacturing entity Guangzhou Hengtai Purification Technology Co., Ltd. (National High-Tech Cert: GR202444009466 , ISO 9001 Cert: 90924Q00571R0M ) hold full government licenses and 63 National Patents + 19 Software Copyrights . 📥 Download Official Red-Stamp License Dossier (PDF) →

## Guangzhou Hengtai Hytek Group (HENGTAI CLEAN): 5-Pillar Turnkey Ecosystem

Founded in 2012 by Chairman Mr. Tan Cheng and headquartered in Guangzhou (Zhuomei Building South Tower, Huadu District, 15 mins from CAN Airport) with a 26,000 m² smart manufacturing base, Guangzhou Hengtai Hytek Group integrates five specialized engineering & manufacturing companies into one unified contract:

### Guangzhou Hengtai Purification Technology Co., Ltd.

Direct CNC sheet-metal & cleanroom equipment manufacturer: SUS304/316L air showers, dynamic laminar pass boxes, H14 gel-seal FFUs, hygienic AHUs, PSA ozone systems, and HT-II boot washers.

### Hengtai Meiye Architectural Design Institute

Backed by design directors from Tsinghua University Academy of Fine Arts , University of the Arts London (Chelsea) & Guangzhou Academy of Fine Arts . Pioneers of "Marketing Factories" & spiral AR VIP Visiting Corridors .

### Guangdong Hengtai Design Engineering Co., Ltd.

Holds national Grade-II Mechanical & Electrical Installation and Grade-II Building Decoration Contractor licenses. Executes ISO 5–8 cleanrooms, sanitary process piping, and epoxy/AGV flooring.

### Guangdong Guochuang Energy Saving Technology Co., Ltd.

Specializes in heat-recovery cleanroom HVAC, low-dew-point rotor dehumidification (RH <40%), building photovoltaic integration, and smart energy monitoring.

### Guangzhou Hengtai Hytek Group Co., Ltd.

Group holding headquarters & regulatory compliance center. Co-founder of the 2025 Hengtai × Ruikong International AI Intelligent Manufacturing Digital Factory (3-in-1 BIM + Process + AGV Logistics simulation cutting construction time by 30%).

### Walk Inside Our Modular GMP Cleanroom in 720° VR

Inspect flush wall panels, coved corners, double-glazed observation windows, ceiling HEPA diffusers, and epoxy floors interactively in 3D VR.

## Authoritative Leadership & 30+ Year Chief Engineering Directorate

Every turnkey cleanroom blueprint and equipment BOM at HENGTAI CLEAN is personally governed by China's top cosmetics, pharmaceutical, and architectural engineering veterans:

### Mr. Tan Cheng

Entered the cosmetics & health manufacturing sector in 2004, founded Tailenju GMP Consulting in 2012 and Guangzhou Hengtai Purification Technology Co., Ltd. in 2015. Pioneered the integration of ISO/GMP cleanroom engineering with architectural brand aesthetics, scaling group output past RMB 100M within 3 years and 1,500+ benchmark factories.

### Mr. Tan Shuping

30+ years of executive GMP factory planning & cleanroom engineering . Director of the Intelligent Equipment Committee of China Cosmetics IUR Collaborative Innovation Platform; Advisor to Jiangsu Daily Chemical Industry Association; former Director of Suzhou Boke & GM of Shanghai Kemei. Enforces Hengtai's signature standard: "Southern Jiangsu Workmanship, Southern China Service."

### Mr. Liu Wei

Educated at Tsinghua University Academy of Fine Arts and Chelsea College of Arts (University of the Arts London) . Leads our 100-person BIM+ architectural & cleanroom design institute. Directed landmark projects for Shanghai Fosun Pharma, Fuerjia Northern Beauty Valley, Proya, Marubi, Xiaomi HQ, Siemens, and ABB .

## Trusted by 1,000+ Listed Pharma, Cosmetics & Food Giants (Verified Jobsite Records)

From 30-ton/day vacuum emulsifying halls and Class 10,000 sterile suites to spiral AR VIP Visiting Corridors , explore authentic, GPS-watermarked engineering logs from Guangzhou Hengtai:

Panoramic glazed inspection gallery overlooking 304/316L vacuum homogenization & sanitary process piping.

8+ vacuum emulsifying pots (50kg–2000kg) with flush interlocked pass boxes & airtight steel doors.

100% precision delivery from AutoCAD blueprint and BIM twin to actual completed physicochemical lab.

Authentic timestamped construction logs: weighing rooms, emulsifying suites, and high-speed airlocks.

Flush-mounted Magnehelic differential pressure gauges (+15 Pa to +30 Pa) & calibrated thermo-hygrometers.

Orbital TIG-welded hygienic stainless steel utility & purified water transfer manifolds on site.

Chief Engineer Mr. Tan Shuping and our engineering delegation at Booth N4K09.

Grand launching ceremony of our AI-Enhanced Smart Manufacturing Digital Plant in Guangzhou.

## Request a 24-Hour Turnkey Cleanroom & Equipment BOQ

Looking for factory-direct pricing without middleman markups? Send our cleanroom HVAC and stainless equipment engineers your layout, target ISO 14644-1 class, or equipment list.

- Stage-1 Budgetary Quote in 4–24 Hours: Itemized EXW / FOB Guangzhou / CIF / DDP unit pricing & container load plan.
- Free Engineering Value-Add: AutoCAD room pressure cascade review, CFM/ACH air-change calculation & utility matrix.
- Download Technical Dossiers: 6 A4 Engineering Spec Sheets (PDF) →

## Compare quotations on the same scope

Ask each supplier to answer the same requirements and identify the evidence for its proposed configuration. An unanswered field is an open question, not proof that a supplier cannot meet the requirement. Availability and acceptance criteria must be confirmed for your order.

| Comparison field | What to request |
| --- | --- |
| Internal usable dimensions | Approved drawing with width, height and depth; distinguish internal from external dimensions |
| Wall interface | Wall thickness, opening, flange, support and installation responsibility |
| Transfer route | Tray or trolley envelope, door swing and handling clearance |
| Interlock behaviour | Mechanical/electrical configuration, power-loss behaviour and agreed function test |
| Air treatment option | Selected airflow configuration and test scope; do not assume a static box filters air |
| Materials and finish | Material grade, thickness, surface finish and cleaning compatibility as ordered |
| Maintenance access | Filter or component replacement access, consumables and spare parts |
| Acceptance package | Model, serial number, inspection results, drawings and instructions matched to the order |

Download the 40-field supplier quotation comparison worksheet (CSV)

Review HENGTAI CLEAN factory source documents · Send your requirements and open questions

Updated: 11 September 2026. This worksheet supports procurement review; it does not certify a supplier or replace engineering acceptance.